Underground Duct Aluminium Tape Armored Cable UV Resistance HDPE Cable Fibre Optical Outdoor Cable
GYTA Armored Loose Tube Single Jacket/Single Armor fiber optic cables are designed to provide high fiber
counts with the flexibility and versatility required for today's most demanding installations, including duct and
underground conduit.
Product Construction:
Fiber:
2-288 fiber
Multi-loose tube gel-filled
Central Strength Member:
Fiberglass reinforced Platic (FRP) or steel wire.
Armor:
Aluminum Tape Armor
Outer Jacket:
Black UV Polyethylene(PE)
Features:
- Up to 288 fibers.
- Loose tube gel-filled construction for superior fiber protection.
- Aluminum tape armor to protect cable from mechanical damage.
- UV and waterproof design.
Application:
- Interbuilding voice or data communication backbone.
- Installed in duct, underground conduit .
Optical Characteristics:
Fiber Type | G.652 | G.655 | 50/125^m | 62.5/125^m | |
Attenuation (+20X) | 850 nm |
|
| <3.0 dB/km | <3.3 dB/km |
1300 nm |
|
| <1.0 dB/km | <1.0 dB/km | |
1310 nm | <0.36 dB/km | <0.40 dB/km |
|
| |
1550 nm | <0.22 dB/km | <0.23 dB/km |
|
| |
Bandwidth | 850 nm |
|
| >500 MHz-km | >200 Mhz-km |
1300 nm |
|
| >500 MHz-km | >500 Mhz-km | |
Numerical Aperture |
|
| 0.200±0.015 NA | 0.275±0.015 NA | |
Cable Cut-off Wavelength cc | <1260 nm | <1450 nm |
|
|
Structure and Technical Specifications
Fiber Count | Nominal Diameter (mm) | Nominal Weight (kg/km) | Max Fiber | Max No. of | Allowable Tensile Load (N) | Allowable Crush Resistance | ||
Short Term | Long Term | Short Term | Long Term | |||||
2~36 | 10.3 | 109 | 6 | 6 | 1500 | 600 | 1000 | 300 |
38~72 | 11.5 | 145 | 12 | 6 | 1500 | 600 | 1000 | 300 |
74~96 | 13.5 | 175 | 12 | 8 | 1500 | 600 | 1000 | 300 |
98~120 | 14.8 | 209 | 12 | 10 | 1700 | 600 | 1000 | 300 |
122~144 | 16.6 | 249 | 12 | 12 | 2000 | 600 | 1000 | 300 |
146~216 | 16.7 | 254 | 12 | 18(2 layers) | 2000 | 600 | 1000 | 300 |
218~288 | 19.0 | 325 | 12 | 24(2 layers) | 2500 | 600 | 1000 | 300 |
Note : This datasheet can only be a reference, but not a supplement to the contract. Please contact our sales people
for more detailed information.
We produce and test cable comply with following standard:
Mechanical Performance | |
Max Tension Performance | IEC 60794-1-2-E |
Max. Operation Tension | IEC 60794-1-2-E1 |
Crush Test | IEC 6079 -1-2-E3 |
Impact Test | IEC 60794-1-2-E4 |
Repeated Bending | IEC 60794-1-2-E6 |
Torsion Test | IEC 60794-1-2-E7 |
Cable bend | IEC 60794-1-2-E11A |
Attenuation Coefficient | ITU-T G.652 |
Structural Test | IEC-60793-1-20 |
Environmental Performance | |
Temperature Cycling | IEC 60794-1-2-F1 |
Water Penetration | IEC 60794-1-2-F5B |
Filing Compound Flow | IEC 60794-1-E1 |